Products List
50 Ohm Coaxial Corrugated Copper Cable 1-5/8 Inch Standard Low Loss, Lower Smoke, Halogen-Free

50 Ohm Coaxial Corrugated Copper Cable 1-5/8 Inch Standard Low Loss, Lower Smoke, Halogen-Free

 Model Number: YL-TZ50-158B


U.S.$ 0.00
0.00
Quantity:
Buy now
Add to cart
  

 Model Number: YL-TZ50-158B


Electrical Specifications

Impedance

50 ohm

Operating Frequency

DC 3 GHz

Max. VSWR

1.10 for 800 - 2200 MHz

1.15 for DC - 3 GHz

Velocity

88%

Pulse Reflection

0.5%

RF Peak Voltage

5.6 kV

Peak Power

310 kW

Max. Voltage for Jacket Spark Test

10 kV

Capacitance

76 pf/m

Inductance

0.185 uH/m

Insulation Resistance

5000M ohm

DC Resistance Inner Conductor

DC Resistance Outer Conductor

0.82 ohm/km @ 8 kV

0.48 ohm/km @ 8 kV

Attenuation

In Attached Table

Mechanical Handling Specifications

Minimum Bending Radius for Multiple Bends

500 mm

Maximum Times of Bending

20

Minimum Bending Radius for Single Bend

310 mm

Bending Moment

45 N-m

Flat Plate Crush Pressure

3.0 kg/mm

Tensile Strength

3480 N

Recommended Clamp Spacing

1.0 m

Mechanical Dimensions & Weight

Inner Conductor OD

17.21 mm

Diameter over Dielectric Material

40.48 mm

Outer Conductor OD

46.49 mm

Diameter over Jacket

51.00 mm

Unit Weight

1.65 kg/m

Material Specifications

Inner Conductor

Threaded Copper Tube

Dielectric

Foam PE

Color of Dielectric

White

Outer Conductor

Corrugated Copper Tube

Jacket Material

PE, (UL1518-1990)

Jacket Color

Black

Fire Proof Standard

IEC 60332-1-2: 2004 Test on eclectic and optical fiber cables under fire conditions - Part 12: test for vertical flame propagation for a single insulated wire or cable-Procedure for 1kw pre-mixed flame.

IEC 60332-3-24: Test on electric and optical fiber cables under fire conditions - Part 3-24: Test for vertical flame spread of vertically-mounted bunched wires or cables - category C.

IEC 61034-2: 2005 Measurement of smoke density of cables burning under defined conditions - Part 2: Test procedure and requirements.

IEC 60754-1: 1994 Test on gases evolved during combustion of materials from cables - Part 1: Determination of the amount of halogen acid gas

IEC 60754-2: 1994 Determination of degree of acidity of gases evolved during the combustion of materials taken from electric cables by measuring PH and conductivity.

Environmental Conditions

Storage Temperature

from -40 °C to 80 °C

Operating Temperature

from -45 °C to 80 °C

Installation / Cutting / Re-packing Temperature

from -25 °C to 60 °C

Packing Info

Lengths per Reel (meter): 300 / 500

Attenuation & Power Table

Frequency (MHz)

Attenuation (dB/100m)

Average Power (kW)

100

0.67

16.40

200

0.98

11.30

300

1.22

9.01

450

1.53

7.18

800

2.13

5.15

900

2.29

4.87

1000

2.43

4.52

1500

3.11

3.54

1800

3.47

3.17

2000

3.71

2.96

2200

4.10

2.77

2500

4.27

2.58

3000

4.95

2.35