Model Number: YL-TZ50-158B
Electrical Specifications
Impedance |
50 ohm |
Operating Frequency |
DC – 3 GHz |
Max. VSWR |
1.10 for 800 - 2200 MHz 1.15 for DC - 3 GHz |
Velocity |
88% |
Pulse Reflection |
0.5% |
RF Peak Voltage |
5.6 kV |
Peak Power |
310 kW |
Max. Voltage for Jacket Spark Test |
10 kV |
Capacitance |
76 pf/m |
Inductance |
0.185 uH/m |
Insulation Resistance |
5000M ohm |
DC Resistance Inner Conductor DC Resistance Outer Conductor |
0.82 ohm/km @ 8 kV 0.48 ohm/km @ 8 kV |
Attenuation |
In Attached Table |
Mechanical Handling Specifications
Minimum Bending Radius for Multiple Bends |
500 mm |
Maximum Times of Bending |
20 |
Minimum Bending Radius for Single Bend |
310 mm |
Bending Moment |
45 N-m |
Flat Plate Crush Pressure |
3.0 kg/mm |
Tensile Strength |
3480 N |
Recommended Clamp Spacing |
1.0 m |
Mechanical Dimensions & Weight
Inner Conductor OD |
17.21 mm |
Diameter over Dielectric Material |
40.48 mm |
Outer Conductor OD |
46.49 mm |
Diameter over Jacket |
51.00 mm |
Unit Weight |
1.65 kg/m |
Material Specifications
Inner Conductor |
Threaded Copper Tube |
Dielectric |
Foam PE |
Color of Dielectric |
White |
Outer Conductor |
Corrugated Copper Tube |
Jacket Material |
PE, (UL1518-1990) |
Jacket Color |
Black |
Fire Proof Standard
IEC 60332-1-2: 2004 Test on eclectic and optical fiber cables under fire conditions - Part 12: test for vertical flame propagation for a single insulated wire or cable-Procedure for 1kw pre-mixed flame. |
IEC 60332-3-24: Test on electric and optical fiber cables under fire conditions - Part 3-24: Test for vertical flame spread of vertically-mounted bunched wires or cables - category C. |
IEC 61034-2: 2005 Measurement of smoke density of cables burning under defined conditions - Part 2: Test procedure and requirements. |
IEC 60754-1: 1994 Test on gases evolved during combustion of materials from cables - Part 1: Determination of the amount of halogen acid gas |
IEC 60754-2: 1994 Determination of degree of acidity of gases evolved during the combustion of materials taken from electric cables by measuring PH and conductivity. |
Environmental Conditions
Storage Temperature |
from -40 °C to 80 °C |
Operating Temperature |
from -45 °C to 80 °C |
Installation / Cutting / Re-packing Temperature |
from -25 °C to 60 °C |
Packing Info
Lengths per Reel (meter): 300 / 500
Attenuation & Power Table
Frequency (MHz) |
Attenuation (dB/100m) |
Average Power (kW) |
100 |
0.67 |
16.40 |
200 |
0.98 |
11.30 |
300 |
1.22 |
9.01 |
450 |
1.53 |
7.18 |
800 |
2.13 |
5.15 |
900 |
2.29 |
4.87 |
1000 |
2.43 |
4.52 |
1500 |
3.11 |
3.54 |
1800 |
3.47 |
3.17 |
2000 |
3.71 |
2.96 |
2200 |
4.10 |
2.77 |
2500 |
4.27 |
2.58 |
3000 |
4.95 |
2.35 |
Address:
No. 3 Dianzi West Street, Xi'an 710065, China
Tel: (86)29 88891870 Fax: (86)29-88891870
Email: enquiry@yolycom.com