Gas Tub Surge Arrestor 0-6GHz Wide Band N Male / Female Bulkhead Lightning Protector Part
    Publish time 2017-04-21 11:48    

Number: YL-BLQF-6GNMNFB

Gas Tub Surge Arrestor 0-6GHz Wide Band N Male / Female Bulkhead Lightning Protector Part

Specifications

Working Frequency

100-6000MHz

Impedance

50 Ω

VSWR

 1.4

Reflection Loss

 -15 dB

Insertion Loss

 0.3 dB

Nominal Discharge Current (8/20 μS)

10 kA

Max. Discharge Current (8/20 μS)

20 kA

Max. DC going through

10 A

Connectors

N Male / N Female Bulkhead

Net Weight

150 g

IP Grade

IP67

Working Temperature

-40  -- +100 

   

Installation

1. Installed to Grounding Cables;

2. IMPORTANT: Grounding Surface Area Minimum 2.5 mm.

 

Maintenance

1. Routine Testing Standard: (Multi-meter) Resistance on Outer Conductor of Cable Should Be Lower than 0.5 mΩ, Otherwise, Grounding Needs to Be Checked or the Arrestor Needs to Be Replaced.

2. Inspection & Testing: Inspection & Testing Needed After Strike or Strikes, although Replacement May Not Be Needed.