Model Number: YL-TZ50-012B
Electrical Specifications
|
Impedance |
50 ohm |
|
Operating Frequency |
DC - 8.8 GHz |
|
Max. VSWR |
1.10 for 800 - 2200 MHz 1.15 for 2690 MHz |
|
Velocity |
83% |
|
Pulse Reflection |
0.50% |
|
RF Peak Voltage |
1.40 kV |
|
Peak Power |
20 kW |
|
Max. Voltage for Jacket Spark Test |
5 kV |
|
Capacitance |
82 pf/m |
|
Inductance |
0.195 uH/m |
|
Insulation Resistance |
5000M ohm |
|
Attenuation |
In Attached Table |
Mechanical Handling Specifications
|
Minimum Bending Radius for Multiple Bends |
30 mm |
|
Maximum Times of Bending |
80 |
|
Minimum Bending Radius for Single Bend |
25 mm |
|
Bending Moment |
2.55 N-m |
|
Flat Plate Crush Pressure |
1.8 kg/mm |
|
Tensile Strength |
800 N |
|
Recommended Clamp Spacing |
0.3 m |
Mechanical Dimensions & Weight
|
Inner Conductor OD |
3.60 mm |
|
Diameter over Dielectric Material |
9.8 mm |
|
Outer Conductor OD |
12.10 mm |
|
Diameter over Jacket |
13.45 mm |
|
Unit Weight |
0.14 kg/m |
Material Specifications
|
Inner Conductor |
Copper-Clad Aluminum |
|
Dielectric |
Foam PE |
|
Color of Dielectric |
White |
|
Outer Conductor |
Threaded Copper Tube |
|
Jacket Material |
Halogen Free, Flame Retardant Polyolefin (FR) |
|
Jacket Color |
Black |
Fire Proof Standard
|
IEC 60332-1-2: 2004 Test on eclectic and optical fiber cables under fire conditions |
|
IEC 60754-2: 2011 Test on gases evolved during combustion of materials from cables |
|
IEC 61034-2: 2013 Measurement of smoke density of cables burning under defined conditions |
|
IEC 60332-3-24: 2000 Test on electric and optical fiber cables under fire conditions |
|
|
Environmental Conditions
|
Storage Temperature |
from -70 °C to 80 °C |
|
Operating Temperature |
from -55 °C to 85 °C |
|
Installation / Cutting / Re-packing Temperature |
from -40 °C to 60 °C |
Packing Info:
Lengths per Reel (meter): 200 / 500 / 800
Attenuation & Power Table
|
Frequency (MHz) |
Attenuation (dB/100m) |
Average Power (kW) |
|
100 |
3.22 |
3.03 |
|
200 |
4.65 |
2.11 |
|
300 |
6.09 |
1.72 |
|
450 |
7.20 |
1.37 |
|
800 |
9.86 |
1.00 |
|
900 |
11.50 |
0.94 |
|
1000 |
12.15 |
0.88 |
|
1500 |
13.80 |
0.70 |
|
1800 |
16.70 |
0.63 |
|
2000 |
16.40 |
0.59 |
|
2100 |
18.40 |
0.56 |
|
2600 |
20.70 |
0.52 |
|
3000 |
20.90 |
0.48 |
Jacket Mark:
YOLYCOM YL-TZ50-012B 50 Ohm 1/2” SFLSHF M/D/Y **** M
Address:
No. 3 Dianzi West Street, Xi'an 710065, China
Tel: (86)29 88891870 Fax: (86)29-88891870
Email: enquiry@yolycom.com
Home l About Us l RF Products l Solutions l News & Info l Conact Us